A 3 year old Used Biotec Xlase  platform system that was only ever used for just 6 months as you will see from the very low shot count that can be seen in the accessories tab. 

The system is complete with 5 different treatment heads

  • Nd:YAG
  • Diode
  • IPL
  • Erbium
  • Q switch 

Training can be provided on the machine

Demonstration and viewing can be arranged

Delivery and installation is not included within the price

Made in EU. CE Certificate of Conformity present.

Manual present for all Lasers.

Call on Sandy Kay on 07999936461 or

email renovaskincare@gmail.com to book for demonstration or for any other queries  

 

 

used x laser
biotec used
biotec goggles
used x laser biotec used biotec goggles

One Advanced and Versatile Laser and light platform that does it all…

Its modular design provides multiple distinct medical and cosmetic solutions all built into one compact unit. 

Treatment heads and applications:

CPL (IPL)

It is used for hair removal, skin rejuvenation, active acne, acne  scars, rosacea and pigmentation. It includes all filters

Diode 

It is mainly used for hair removal, works on all skin types and delivers permanent hair reductions within 6 sessions. A whole back can be done in 10 minutes. Can be used for Skin Rejuvenation

ND-Yag 

It is used for hair removal for skin type 5 and 6 and also for spider vein, thread vein treatments, fungal nail treatment and skin rejuvenation. Different spot size spacer included.

Q-Switch 

It is used for tattoo removal –black and coloured, pigmentation treatment, carbon peeling. Different lenses included.

Erbium 

It is used for pigmentation, scars, skin resurfacing and stretch marks. It includes Ablate and Fractional Laser

For the treatment of: –

  • Benign Pigmented Lesions –
  • Benign Vascular Lesions –
  • Microvascular Lesions –
  • Acne –
  • Hair Removal –
  • Acne Scarring –
  • Tattoo Removal –
  • Skin Peeling –
  • Hyperhidrosis –
  • Onychomycosis –
  • Acne –
  • Non Ablative Skin Rejuvenation 

Advantages

• Numerous aesthetic/medical applications;
• High output energy for greater efficacy;
• Expandable and upgradable;
• High patient and clinical staff satisfaction;
• Easily transportable from room to room

The Used Biotec Xlase platform will come with 

5 treatment heads

  • CPL (IPL) – Lamp life remaining 49K out of 50K.

  • Diode – Lamp Life remaining 19.4 million out of 20 million

  • ND-Yag -Lamp Life remaining 0.49 out of 0.5 million

  • Q-Switch -Lamp Life remaining 0.489 out of 0.5 million

  • Erbium – Lamp Life remaining 0.49 million out of 0.5 million

The laser will also come with

  • 5 pairs of protective eyewear
  • Different IPL filters
  • Spacer for Nd:YAG and Q switch
  • Ablative and fractional heads for erbium 
General specifications System cooling Water and Air  
Skin Cooling Ice Type integrated
Interface Touchscreen Color LCD display 7''
   
Dimensions 530 x 650 x 350 mm
Weight 35 Kg
 
Laser Type Nd:YAG - Vascular lesions
  Wavelenght 1064 (532 nm with KTP lens) - Skin rejuvenation
  Energy Density 500 J cm2 (max) - Hair removal
  Pulse Duration (Long Pulse) from 5 µs to 40ms - Onychomycosis
Nd:YAG Pulse Duration (Short Pulse) from 250μs to 5000μs - Non Ablative
  Repetition Rate Single pulse - 3Hz (max)  
  Spot Size 2.5 - 4 - 5 - 7 - 10  
  Laser Emission Control footswitch  
  Aiming Beam diode laser, 4mW @ 635nm  
 
Source Xenon Lamp - Hair Removal
  Spectrum of Emission 550 - 1200 nm; 550 - 950n m - Acne
  Energy per pulse 650 - 950 nm; 420 - 1200 nm; - Skin Rejuvenation
  Pulse Duration 695 - 1200 nm; 755 - 1200 nm - Vascular Lesions
CPL Delay Between Pulses 25 J/cm2 (max)  
  Number of pulses from 1 to 60 ms  
  Repetition Rate from 5 to 60 ms  
  Treatment Area from 1 to 5  
  Emission Control Single pulse - 3Hz (max)  
    50mm X 10mm (5cm2)  
    footswitch and handpiece switch  
 
Laser Type High-power diode - Hair Removal
  Wavelength 810 nm - Skin Rejuvenation
Diode Pulse width < 500ms - Microvascular Lesions
    < 60ms using continous pulses  
    60-500ms using burst of pulses  
  Repetition rate Variable up to 10 Hz  
  Fluence to tissue Variable up to 60 J/cm2  
  Spot size 9x9 mm standard  
  Skin cooling Water cold sapphire  
  Expected lifetime 15.000.000 pulses  
  Power output 2.000 W  
 
Laser type CR:YAG - Tattoos removal
  Wavelenght 1064 (532 nm with KTP lens) - Skin peeling
Q-switched Pulse Duration 9-10 nsec - Pigmented Lesions
Tattoos removal and Spot Size 2,5 - 4 - 5 - 6 - 7 mm - Vascular Lesions
pigmented lesions Pulse Repetition Rate from 1 to 6Hz  
  Energy Density passive Q-switched 7 mm spot size 2,5 J/cm2  
 
Pulse Duration Short, Medium, Long - Skin rejuvenation
  Spot Size Pixel 7x7 or 10x10 or 20x20 - Skin peeling
Er:YAG Pulse Repetition Rate 2Hz (Non-Stacking) - Pigmented lesions
Fractional skin resurfacing   5Hz (Stacking) - Acne scarring
  Energy Density Short 200 - 1200 mJ/P - Stretch marks
    Medium: 600 - 1800 mJ/P  
    Long: 800 - 2500 mJ/P  
Er:YAG Pulse Duration Short, Medium, Long  
Ablative akin resurfacing Spot Size Erbium 4 m
  Pulse Repetition Rate Up to 4 Hz
  Energy Density Short 200 - 1200 mJ/P
    Medium: 600 - 1800 mJ/P
    Long: 800 - 2500 mJ/P